DLDOBSEL=LOW, ALDOSSEL=VBAT, MLDOBSEL=LOW, ALDOBSEL=LOW, MLDOSSEL=VBAT, DLDOSSEL=VBAT
Control
ALDOOVAL | Analog LDO Output Value Select. |
ALDOBSEL | Analog LDO Bias Select. 0 (LOW): Select a low bias for the analog LDO. 1 (HIGH): Select a high bias for the analog LDO. |
ALDOSSEL | Analog LDO Source Select. 0 (VBAT): Select the VBAT pin as the input voltage to the analog LDO. 1 (DCDC): Select the output of the DC-DC converter as the input voltage to the analog LDO. |
MLDOOVAL | Memory LDO Output Value Select. |
MLDOBSEL | Memory LDO Bias Select. 0 (LOW): Select a low bias for the memory LDO. 1 (HIGH): Select a high bias for the memory LDO. |
MLDOSSEL | Memory LDO Source Select. 0 (VBAT): Select the VBAT pin as the input voltage to the memory LDO. 1 (DCDC): Select the output of the DC-DC converter as the input voltage to the memory LDO. |
DLDOOVAL | Digital LDO Output Value Select. |
DLDOBSEL | Digital LDO Bias Select. 0 (LOW): Select a low bias for the digital LDO. 1 (HIGH): Select a high bias for the digital LDO. |
DLDOSSEL | Digital LDO Source Select. 0 (VBAT): Select the VBAT pin as the input voltage to the digital LDO. 1 (DCDC): Select the output of the DC-DC converter as the input voltage to the digital LDO. |